PURPOSE: To lay down a method for environment monitoring.
SCOPE: This procedure applies for an entire unit.
RESPONSIBILITY : Production, Q.C and Store supervisor.
PROCEDURE:
1. Record the temperature & humidity in the environmental monitoring chart.
2. Regulate the A/C or Dehumidifier if the temperature of a particular area is out of the prescribed
limit.
3. The limit is specified below:
| Injection Washing | 25-27°C | 50%max | 
| Injection area | 25-27°C (class1000) | 50%max | 
| Dry Injection | 23-25°C | 35-40% | 
- Record the result in the following format
 
| Date | Area | Time | Limit | Observation | Remarks | 
| Author: (GM Production) | Checked by: (QA Manager) | Authorised by: (Director Technical) | 
| Date: | Date : | Date : | 
(Review date on or before 12 months from date of authorization)